Message:

FIX: NanoCreator - GCD() failed on zero arguments, fixed length of tubes.

  • BUGFIX: GCD() did not check for its arguments being zero before division.
  • FIX: The length of the constructed tubes did not match theoretical values (from printout of www.atomistix.com table)
    • The problem was that the found (c,d) values were not divided by their GCD values. Hence, NTs became too long.
  • Nanotubes (12,m) now are all confirmed with respect to radius, length and atom count against the atomistix.com table